:: دوره 2، شماره 2 - ( مجموعه مقالات اندودانتیکس 1390 ) ::
جلد 2 شماره 2 صفحات 0-0 برگشت به فهرست نسخه ها
SHAPING ABILITY OF NICKEL-TITANIUM ROTARY INSTRUMENTS IN CURVED ROOT CANALS
چکیده:   (1739 مشاهده)

 Introduction:

  Disinfection and subsequent obturation of the root canal space require adequate mechanical enlargement of the canals. The purpose of this in vitro study was to compare the shaping ability of Mtwo, RaCe and Medin rotary instruments during the preparation of curved root canals.

 Materials and Methods:

 Sixty mesiobuccal root canals of mandibular molars with severe curvatures between 25-35° and radius of 4-9 mm were randomly divided into three groups of 20 canals each. Using pre- and post-instrumentation radiographs, straightening of the canal and the apical transportation were determined with AutoCAD software. The data were analyzed using Chi square, analysis of variance, and post-hoc tests and the significance level was set at P<0.05.

 Results:

 Mtwo instruments maintained the canal curvature significantly better than Race and Medin instruments (P<0.05). There was significant difference between the rotary instruments for iatrogenic transportation of the major foramen (P>0.05).

 Conclusions:

  Under the conditions of this in vitro study, Mtwo instruments seemed superior to the two other rotary instruments.


 Source: Iranian Endodontic Journal

 Full Text

واژه‌های کلیدی: Dental Instruments; NiTi Alloy; Root Canal; Root Canal Preparation
     
نوع مطالعه: پژوهشي | موضوع مقاله: اندودانتیکس
دریافت: 1392/7/8 | انتشار: 1390/10/25


XML     Print



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 2، شماره 2 - ( مجموعه مقالات اندودانتیکس 1390 ) برگشت به فهرست نسخه ها