[Home ] [Archive]   [ فارسی ]  
Search in website

Advanced Search
..
:: Volume 6, Issue 6 (1-2012) ::
3 2012, 6(6): 0-0 Back to browse issues page
Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study
Panos Papaspyridakos * , Kunal Lal , George Shelby White , Hans-Peter Weber , German O. Gallucci
Abstract:   (2461 Views)

 Purpose: The effect of different implant impression techniques on the accuracy of casts has been investigated mostly in vitro, and clinically relevant evidence is scarce. The purpose of this study was to investigate the effect of implant impression techniques—specifically, splinted versus nonsplinted—on the accuracy of fit of fixed implant prostheses in edentulous patients.
Materials and Methods: This clinical study included 12 edentulous patients (13 edentulous arches). All patients had undergone computer-guided, prosthetically driven implant surgery. Splinted (with acrylic resin) and nonsplinted pickup implant impression techniques were used to generate two different casts. Intraoral verification jigs were made to fabricate a third index cast (prosthesis fabrication cast) these made up a control group. All patients were definitively rehabilitated with one-piece zirconia prostheses. The accuracy of fit of each prosthesis was evaluated indirectly by examining them clinically and radiographically while they were fit on the generated casts.
Results: Of the 13 splinted casts, 12 presented with accurate clinical fit when the zirconia prosthesis was seated on its respective cast. Only 6 of the 13 nonsplinted casts showed accurate clinical fit. The zirconia prostheses fit accurately on all respective casts of the control group (prosthesis fabrication cast) as well as intraorally. The differences between the test groups and between the nonsplinted and control groups were statistically significant. No statistically significant differences were found between the splinted and control groups.
Conclusion: There is clinical evidence that the splinted impression technique generates more accurate implant impressions and master casts than the nonsplinted technique for complete-arch, one-piece fixed prostheses.


  Source : Journal of Oral & Maxillofacial Implant

  Full text

Keywords: accuracy of fit, dental implants, implant impressions, nonsplinted techniques, splinted techniques
     
Type of Study: Research | Subject: Periodontology
Received: 2012/02/13 | Published: 2012/01/15
Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Papaspyridakos P, Lal K, White G S, Weber H, Gallucci G O. Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study. 3 2012; 6 (6)
URL: http://idai.ir/article-1-309-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 6, Issue 6 (1-2012) Back to browse issues page
جامعه اسلامی دندانپزشکان Islamic Dental Association of IRAN

کلیه حقوق سایت متعلق به جامعه اسلامی دندانپزشکان ایران است. تماس با ما

Persian site map - English site map - Created in 0.05 seconds with 34 queries by YEKTAWEB 4652